Part Number Hot Search : 
PP2HCS 5KP15A S2055 TR3D336 SWAK0H NZH3V3A 5KP15A BCR141L3
Product Description
Full Text Search
 

To Download SCT32110 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 S/TRI/SCTx2110/B/27/05/2003
page 1 / 2 F/GB
Relais Statique Triphase Three Phase Solid State Relays
Les relais SCT se composent de 3 relais statiques separes pilotes par une commande commune en tension continue. Ils permettent le pilotage de charges alternatives 12A telles que resistances, petits moteurs..., sur un reseau de 12 a 440VAC mono ou triphase. Ils sont adaptes pour les applications necessitant un faible encombrement et un faible cout. The SCT relays are made up of 3 separate relays controlled by a common DC voltagecontrol. They are designed to control 12A AC loads such as resistors, small motors, etc, on a mains from 12 to 440VAC, either single or three phase. They are well suited for applications with compact-size and low cost in mind.
Dimensions / Dimensions: SCT32110-SCT62110
0,2 0,2
SCTx2110
Connecteurs avec ressort type cage Cage clamp connection from WAGO
=
0,2
35,6
Bornes a ressort/Plugs :
26 14 7,5
Circuit equivalent/Equivalent circuit :
=
8,9 5 6
2 3 zero volt
19,6 8,2 * 1
0,2
10,3 10,3
18
1 7 zero volt
2 3 4
40,5 9
+0,3
7,5
0,1
58,5 0
O4,7
0,1
0,1
47,6 8 7
26 18
11 5
4 5 zero volt 8
1,2 29
0,5
5,1
5 44,5
+0,2
0,2
5,5
0,2
6
Caracteristiques d'entree (a 20C) / Input characteristics (at 20C) Parametre / Parameter Symbol Tension nominale / Nominal control voltage Uc nom Tension maximum de commande / Maximum conrol voltage Uc max Tension minimum de commande / Minimum conrol voltage Uc min Courant nominal / Nominal current (@Uc nom) Ic nom Courant maximum de commande / Maximum conrol current Ic max Courant minimum de commande / Minimum conrol current Ic min Tension de relachement / Release voltage Ur DEL / LED Resistance d'entree / Input impedance ==> Ic=(Uc-Ur)/Rc Rc Tension maximum inverse / Maximum reverse voltage Urv Caracteristiques entree-sortie (a 20) / Input-output characteristics (at 20) U isolement entree-sortie / Input-output isolation voltage Uiso U isolement sortie-semelle / output-case isolation voltage Uiso
Plage de temperature de fonctionnement / Operating t range Poids / Weight
Unit
4 - 30 9 - 90 4 70 ma @24VDC
V V V mA mA mA V
90 3 0,8 Non/no
330
V
30
4000 2500 -40 / +100 100
V V C g
Proud to serve you
All technical caracteristics are subject to change without previous notice. Caracteristiques sujettes a modifications sans preavis.
celduc
r e l a i
s
S/TRI/SCTx2110/B/27/05/2003
page 2 / 2 F/GB
Caracteristiques d'entree (a 20C) / Input characteristics (at 20C) Types / Types Caracteristiques de sortie (a 20C) / Output characteristics (at 20C) Modeles / References Tension nominale / Nominal voltage Plage tension de fonctionnement / Operating range Tension crete / Peak voltage Niveau de synchronisation / Synchronizing level Courant nominal par ligne (voir les caracteristiques thermiques) / Nominal current in line (see thermal curves) Courant de surcharge accidentel admissible maximum (10ms) / Maximum accidental overload current (10ms) Chute tension directe max. (In) / On state voltage drop (In) Courant de fuite etat bloque ( Unom./50Hz) / Off state leakage current ( Unom./50Hz) Courant de charge minimum / Minimum load current Courant de maintien / Holding current Temps de fermeture (50Hz) / Turn on time Temps d'ouverture (50Hz) / Turn off time Frequence d'utilisation / Operating frequency dv/dt etat bloque / Off state dv/dt di/dt non repetitif/ No repetitive di/dt I2t(<10ms) Homologation / Approval Resistance thermique jonct.-semelle/ Junct.-case thermal resistance * Resistance thermique jonct.-ambiant/ Junct.-ambient thermal resistance *Resistance thermique pour un triac/ Thermal resistance for one triac 0,1 10 10-440 500 20 72 Nous consulter Consult us 2,1 11,2
Asynchrone / Random SCT32110
Synchrone / Zero-cross SCT62110
400 12- 440 850 12 120 1,6 0,3 5 50 10 10
VRMS VRMS VPEAK V ARMS APEAK V mARMS mARMS mA ms ms Hz V/s A/s A2s C/W C/W
Courbe thermiques / Thermal curves : Courbes permettant de determiner le radiateur adequat /Curves which allow to determinate the right heatsink
60
0 0,9 5 5K
Courbe de surcharge admissible/ Over current curve : Courant crete non repetitif admisible pour un nombre de periodes/ Non repetitive surge peak on-state current versus number of cycle
1 1,
50
Fu ll o n-s tat e
40
Courant de surcharge /Overload current (A)
2 2K /W
/W
120 110 100 90 80 70 60 50 40 30 20 10 0 1 10 100 1000
Total wasted power (W)
30
20
% 50
cle cy uty d
3K /W
with
out
10
heat
sink
Nombre de periodes (50 Hz) / Number of cycles (50 Hz)
0 0 2 4 6 8 RMS load current (A) 10 12 0
10 20 30 40 50 60 70 80 90 100 Ambient temperature (C)
celduc
r e l a i s
www.celduc.com
Rue Ampere B.P. 4 42290 SORBIERS - FRANCE E-Mail : celduc-relais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tel. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tel. +33 (0) 4 77 53 90 19


▲Up To Search▲   

 